Reliable Single Interlock Preaction System Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Détecteurs de fumée Reliable Single Interlock Preaction System. Reliable Single Interlock Preaction System Technical data Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 26
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model DDX PrePaK, Type D
Preaction System
2”(50mm), 2
1
/
2
” (65mm) &
3”(80mm) Sizes
Bulletin 740 Rev. B
Bulletin 740 Rev. B
Instructions for
Installation, Operation,
Care and Maintenance
10 PSI (0,7 bar) Pneumatic Supervising Pressure
Single Interlock
Double Interlock
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - Care and Maintenance

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523Model DDX PrePaK, Type D Preaction System2”(50mm), 21/2”

Page 3

11.Fig. 6

Page 4 - System Design Considerations

Figure 7 — Wiring Diagram12.

Page 5

Inspection And Testing Of Single And Double Interlock SystemsRefer to Fig. 8.Water supply — Verify that the valve controlling wa-ter supply to the del

Page 7

POTTER PROGRAM #6OUTPUTSZONES*Supervisory 2#1Conventional#2Manual Release#3Waterfl ow#4Low Air Supervisory#1 ALARM X X#2 WATERFLOW X#3 SUPERVISORY X X#

Page 8

16.ZONE 1ZONE 2ZONE 3ZONE 4OUTPUT 1OUTPUT 2OUTPUT 3OUTPUT 4PROGRAMMODERUNMODEAC POWERPOWER TBLSYSTEM TBLSUP TBLGROUNDFAULTSUP 1/ABORTSUPERVISORY 2COMM

Page 9

Potter Program #7Single Interlock Programming Instructions (Single Hazard - Cross-Zoned, 2 Alarm Zones, 1 Waterfl ow Zone and 2 Supervisory Zones)Apply

Page 10

18.ZONE 1ZONE 2ZONE 3ZONE 4OUTPUT 1OUTPUT 2OUTPUT 3OUTPUT 4PROGRAMMODERUNMODEAC POWERPOWER TBLSYSTEM TBLSUP TBLGROUNDFAULTSUP 1/ABORTSUPERVISORY 2COMM

Page 11

Potter Program #9Double Interlock Programming Instructions(Single Hazard, Cross Zoned, 2 Alarm Zones(1 Detection & 1 Low Air), 1 Waterfl ow Zone,a

Page 12 - Figure 7 — Wiring Diagram

2.General DescriptionThe Reliable Model DDX 2” (50 mm), 2½” (65 mm) and 3” (80 mm) PrePaKs are completely self-contained, supervised pre-action system

Page 13

20.Fig. 11ZONE 1ZONE 2ZONE 3ZONE 4OUTPUT 1OUTPUT 2OUTPUT 3OUTPUT 4PROGRAMMODERUNMODEAC POWERPOWER TBLSYSTEM TBLSUP TBLGROUNDFAULTSUP 1/ABORTSUPERVISOR

Page 14

Potter Program #10Double Interlock Programming Instructions(Single Hazard, Cross Zoned, 3 Alarm Zones (2 Detection & 1 Low Air), 1 Waterfl ow Zone,

Page 15 - Potter Program #6

22.ZONE 1ZONE 2ZONE 3ZONE 4OUTPUT 1OUTPUT 2OUTPUT 3OUTPUT 4PROGRAMMODERUNMODEAC POWERPOWER TBLSYSTEM TBLSUP TBLGROUNDFAULTSUP 1/ABORTSUPERVISORY 2COMM

Page 16 - Figure 9 — Wiring Diagram

Custom Program #1 (For New York City Compliance)Single Interlock Programming Instructions for New York City Compliance (Single Hazard, 2 Alarm Zones,

Page 17 - POTTER PROGRAM #7

24.ZONE 1ZONE 2ZONE 3ZONE 4OUTPUT 1OUTPUT 2OUTPUT 3OUTPUT 4PROGRAMMODERUNMODEAC POWERPOWER TBLSYSTEM TBLSUP TBLGROUNDFAULTSUP 1/ABORTSUPERVISORY 2COMM

Page 18

25.Ordering Information:Model DDX 2” (50 mm), 21/2” (65 mm) and 3” (80 mm) PrePAK Part Number Code Key22532 = PrePaK Assembly with 2” (50 mm)Grooved E

Page 19 - POTTER PROGRAM #9

The Reliable Automatic Sprinkler Co., Inc.(800) 431-1588 Sales Offices(800) 848-6051 Sales Fax(914) 829-2042 Corporate Officeswww.reliable

Page 20

Fig. 13.

Page 21 - POTTER PROGRAM #10

4.ApprovalsUnderwriters Laboratories, Inc. Listed and Certified for Can-ada* (cULus) as an assembled unit in the “Special System Water Control Valves

Page 22

5.pressor. The air compressor is connected to an 2 gallon (9.1 liter) ASME rated storage tank. This tank functions as a reservoir, pro-viding make-u

Page 23 - POTTER PROGRAM #1

6.Energizing the releasing solenoid valve allows the deluge valve’s push-rod chamber to be vented to drain through its outlet. Since the pressure cann

Page 24

7.ZONE 1ZONE 2ZONE 3ZONE 4OUTPUT 1OUTPUT 2OUTPUT 3OUTPUT 4PROGRAMMODERUNMODEAC POWERPOWER TBLSYSTEM TBLSUP TBLGROUNDFAULTSUP 1/ABORTSUPERVISORY 2COMMO

Commentaires sur ces manuels

Pas de commentaire